Cookies on the SKF website

We use cookies to ensure that we give you the best experience on our websites and web applications. By continuing without changing your browser settings, we assume you give your consent to receive cookies. However, you can change your browser cookie setting at any time.

Single-line metering devices

Lubricant metering devices for single-line automatic lubrication systems

Working principle:

  • Only one lubricant point is assigned to each lubricant outlet.
  • Pre-lubrication metering devices feed the quantity of lubricant to the lubrication point during the pressure build-up in the main line. i.e. while the pump is running.
  • Re-lubrication metering devices do not feed the lubricant to the lubrication point until the pressure relief process in the main line has been completed, i.e. after the pump has been turned off. Relubrication metering devices work like spring-energy accumulators. If, for example, lubrication points are subject to heavy loads during the lubricating cycle, the lubricant is stored in the metering devices and not discharged until the friction points move or are relieved of pressure.

Models

  • Multi-point devices are built directly into the main line.
  • Single-point devices (metering units) are mounted on manifolds.
  • Single metering units are screwed directly into the lubrication points.
  • Overview

    ProductMetering quantityOperating pressure

    cm³/strokein³/strokebarpsi

    Metering devices for oil
    3410,01-0,160.0006-0.00976-8087-1160
    3400,01-0,160.0006-0.00976-8087-1160
  • Related downloads
  • Applications
  • SKF logo