Cookies on the SKF website

SKF uses cookies on our websites to align the information shown as closely as possible to our visitors’ preferences, such as country and language choices. Will you accept SKF cookies?

QSL

High-pressure metering devices for use in single-line lubrication systems

QSL metering device

QSL metering devices are designed for 300 bar pressure. As a result, NLGI 2 greases can be pumped at temperatures below zero without problems. All metering devices operate independently of each other. This means that in the event of a blockage or fault of one metering device, all other metering devices will continue to supply lubricant. A control pin on top shows proper function of each injector.

Features and benefits:

  • Suitable for use with manifolds from 1 to 6 ports to match number of lube points; must be ordered separately
  • Corrosion-resistant, black-cromated or nickel-plated surface
  • Each indicator stem permits visual check of operation
  • Can be removed easily for inspection or replacement
  • Controlled via main line
  • Technical features
    Function principlemetering device
    Outlets1 to 6
    Metering0,05 to 0,4 cm³0.003 to 0.024 in³
    Lubricantgrease NLGI 0, 1, 2
    Operating temperature–40 to +70 °C–40 to +158 °F
    Operating pressure140-300 bar2030-4350 psi
    Relief pressure≤60 bar≤870 psi
    Materialsteel, black cromated, polyurethane
    Connection main lineG 3/8 for steel pipe
    Connection outletG 1/8 for tubes/hoses
    Lubricant pointsolderless pipe connection, DIN 3862
    or SKF quick connector
    Dimensionslength: max. 160 mm
    ø 28 mm
    6.3 in
    ø1.1 in
    Mounting positionany
  • Applications
SKF logo